Power Supplies Voltmeter etc.

Home/ Product

Moving Coil DC Voltmeters / Ammeters with front terminals EDM-80 Scale length 60mm, MR-100 Scale length 100mm.

GED-  01 Galvanometer EDM-80 Sensitivity 20µA / Division  30-0-30
GED - 02 Galvanometer EDM-80 Sensitivity 10µA / Division  30-0-30
GED – 03 Galvanometer EDM-80 Sensitivity 2µA / Division  30-0-30
GED – 04 DC Voltmeter EDM-80 1V to 600V in any range
GED – 05 DC Milli Voltmeter EDM-80 50mV, 100mV, 150mV, 200mV,500mV, 1000mV
GED – 06 DC Ammeter EDM-80  0 to 10Amp Any range
GED – 07 AC Voltmeter (Rectifier Type) EDM-80  0-3V to 600V Any range
GED – 08  AC Mill Voltmeter (Rectifier Type) EDM-80  0-100mV to 1000mV
GED – 09 AC Ammeter (Rectifier Type) EDM-80 0-1.5 to 5 Amps Any range
GED – 10 AC Ammeter (Transformer Type) EDM-80 0-1 to 10 Amps Any range
GED – 11 AC Milli Ammeter (Rectifier Type) EDM-80  0-1 to 1000mA Any range
GED – 12 Galvanometer MR-100  Sensitivity 20µA / Division  30-0-30
GED – 13 Galvanometer MR-100  Sensitivity 10µA / Division  30-0-30
GED – 14 Galvanometer MR-100  Sensitivity 2µA / Division  30-0-30
GED – 15 DC Voltmeter MR-100  1V to 600V in any range
GED – 16 DC Milli Voltmeter MR-100 50mV, 100mV, 150mV, 200mV,500mV, 1000mV
GED – 17 DC Ammeter MR-100 0 to 10Amp Any range
GED – 18 DC Milli Ammeter MR-100 0-1 to 1000mA Any range
GED – 19 AC Voltmeter (Rectifier Type) MR-100 0-3V to 600V Any range
GED – 20 AC Mill Voltmeter (Rectifier Type) MR-100 0-100mV to 1000mV
GED – 21 OHM’S Meter Moving Coil Type
GED – 22 Digital Voltmeter 3-1/2 digit LCD display with front terminals
GED – 23 Portable Volt Meter DC in carrying case scale length 144mm
GED – 24 Portable Volt Meter AC in carrying case scale length 144mm
GED – 25 Portable Ammeter DC in carrying case scale length 144mm
GED – 26 Portable Ammeter AC in carrying case scale length 144mm
GED – 27 Demonstration Galvanometer
GED – 28 Demonstration Voltmeter
GED – 29 Demonstration Ammeter
GED – 30 Ballistic Galvanometer resistance 100 or 500 ohms
GED – 31 Spot Reflecting Galvanometer resistance 125 or 500 ohms Battery or Mains operated as per customer requirement
GED – 32                       Connecting Leads Red and Black 16” long with 4mm Banana Plug

Battery Eliminators, Battery Chargers, Power Supplies

GED  – 40 Battery Eliminator 2v-12v in 2v steps 1 Amp
GED – 41 Battery Eliminator 2v-12v in 2v steps 2 Amps
GED – 43 Battery Eliminator 2v-12v in 2v steps 3 Amps
GED – 44 Battery Eliminator 2v-12v in 2v steps 5 Amps
GED – 45 IC Regulated Battery Eliminator 2- 12V / 3 Amps
GED – 46 IC Regulated Battery Eliminator 2- 12V / 5 Amps
GED – 47 Battery Eliminator AC/DC Combine 2v-12v in 2v steps 1 Amp
GED - 48 Battery Eliminator AC/DC Combine 2v-12v in 2v steps 2 Amps
GED – 49 Battery Eliminator AC/DC Combine 2v-12v in 2v steps 3 Amps
GED – 50 Battery Eliminator AC/DC Combine 2v-12v in 2v steps 5 Amps
GED – 51 Battery Charger 2v-12v in 2v steps 2 Amps
GED – 52 Battery Charger 2v-12v in 2v steps 3 Amps
GED – 53 Battery Charger 2v-12v in 2v steps 5 Amps
GED – 54 Step Down Transformer 2-12vA/C / 1 Amp
GED – 55 Step Down Transformer 2-12vA/C / 2 Amps
GED – 56 Step Down Transformer 2-12vA/C / 3 Amps
GED – 57 Step Down Transformer 2-12vA/C / 5 Amps
GED – 58 Step Down Transformer 6v – 30v / 3 Amps for Callender & Barne’s App.
GED – 59 Step Down Transformer 8v / 3 Amps for Electromagnet & Sonometer
GED – 62 IC Regulated Power Supply 2-15v /2 Amps with 2 Analogue Meter
GED – 63 IC Regulated Power Supply 2-12v /3 Amps with 2 Analogue Meter
GED – 64 IC Regulated Single Power Supply 0-15v / 1Amp with 2 Digital meter
GED – 65 IC Regulated Single Power Supply 0-15v / 2Amps with 2 Digital meter GED – 66IC Regulated Single Power Supply 0-15v / 3Amps with 2 Digital meter
GED – 67 IC Regulated Single Power Supply 0-30v / 1Amps with 2 Digital meter
GED – 68 IC Regulated Single Power Supply 0-30v / 2Amps with 2 Digital meter
GED – 69 IC Regulated Single Power Supply 0-30v / 3Amps with 2 Digital meter
GED – 70 IC Regulated Single Power Supply 0-300v / 30mA with 2 Digital meter
GED – 71 IC Regulated Single Power Supply 0-300v / 1Amp with 2 Digital meter
GED - 72 IC Regulated Double Power Supply 15-0-15v / 1Amp with 4 Digital meter
GED – 73 IC Regulated Double Power Supply 15-0-15v / 2Amp with 4 Digital meter
GED – 74 IC Regulated Double Power Supply 30-0-30v / 1Amp with 4 Digital meter
GED – 75                                             IC Regulated Double Power Supply 30-0-30v / 2Amp with 4 Digital meter

Special Purpose DC Regulated Power Supplies

GED –76 Fixed Output Regulated Power Supply +5V / 1 Amp
GED – 77 Fixed Output Regulated Power Supply +5V / 2 Amp
GED – 78 Fixed Output Regulated Power Supply +12V / 1 Amp
GED – 79 Fixed Output Regulated Power Supply +12V / 2 Amp
GED – 80 Power Supply for Analog to Digital Lab modules ±5V/250mA, ±12V/250mA
GED – 81 Power Supply for Electrophoresis Apparatus with Digital Meters
GED – 82 Power Supply for Diode / Triode Valve Characteristics
GED – 83 Power Supply for Tetrode / Pentrode Valve Characteristics
GED – 84 Power Supply for Millikan’s Oil Drop Apparatus
GED – 85 Low Tension AC/DC power supply 0-25VAC/10Amp, 0-25VDC/10Amp
GED – 86 Kelvin Bridge DC Source 0-12V / 5 Amp with volt meter
GED – 87 Industrial Kelvin Bridge DC Source 0-60V / 10Amp with Volt meter
GED – 88 DC Power Supply 0-100V / 10 Amp with one meter
GED – 89 Electronic Standard Cell 1.018 VDC
GED – 90 Electronic Daniel Cell 1.08 VDC
GED – 91       Electronic Lachlanche cell 1.5 VDC